High-Performance Steel Fire Doors 

Blockade Barriers supplies and installs high-performance steel fire doors for demanding commercial and industrial environments. The Durasub range includes doors tested to provide up to 4 hours of fire resistance, engineered to perform where safety and reliability are critical. 

KEY FEATURES
  • Fire rated up to 4 hours 

  • Door sizes up to 5m high and 6.8m wide 

  • Up to 3 Passive Air Flow Louvres per leaf 

  • Paint or powder-coat finishes available 

ABOUT
Durasub Passive Air Flow
Fire Door Range 

The Durasub Passive Air Flow Fire Door range offers a level of flexibility rarely found in fire-rated steel doors. Each doorset is purpose-built to meet exact project requirements, with tested solutions available for openings up to 5 m high and 6.8 m wide. This makes the Durasub Passive Air Flow range ideal for complex or non-standard openings where fire performance cannot be compromised. 

​

Available in single and double-leaf configurations, Durasub Passive Air Flow Fire Doors are suitable for both internal and external applications. 

 

The doors are constructed from a high-strength composite panel of fibre-reinforced cement mechanically bonded to punched steel sheets on both outer faces. This construction delivers excellent impact resistance, durability, and long-term reliability in demanding environments. 

​

Durasub Passive Air Flow Fire Doors incorporate intumescent air transfer louvres that allow continuous airflow under normal operating conditions while maintaining fire protection performance.

​

The intumescent air transfer louvres can be installed within the door leaves, above the door, or as a combination of both configurations, with up to three louvres permitted per door leaf.

​

In the event of a fire, the intumescent material expands automatically to seal the ventilation openings, maintaining the fire-resistance integrity of the door assembly and preventing the passage of flames and hot gases through the ventilation path.

TECHNICAL SPECIFICATIONS
Passive Airflow Fire Doors Durasub Blockade Barriers
FEATURES

Fire Resistance Level  FRL -/120/30 

 

Structural Opening

  • Height: 5,000 mm

  • Width: 6,800 mm

 

Door Leaf

  • Overall Thickness: 50 mm

  • Material: 9.5 mm thick composite panel of fibre-reinforced cement mechanically bonded to punched steel sheets on both outer faces.

  • ​Joint Construction: Mitred and welded

  • Intumescent Louvres: Up to 3 per leaf with a maximum size of 600mm x 300mm  

​

Frame

  • Frame Options:

    • Unequal angle frame: 150 × 90 × 8 mm

    • Pressed metal frame: up to 50 mm wide with 25 mm rebate

  • Capping: 90 × 50 × 3 mm thick angle section

  • Joint Construction: Mitred and welded joints

  • Configuration: Single or double rebate with three-sided frame

  • Threshold Plate: 70 × 10 mm thick mild steel plate

​

Finish

  • Frame and Leaf: Paint finish or powder coating

Passive Airflow Fire Doors Durasub Blockade Barriers
HARDWARE (standard)

Hardware as Standard​

  • Full-length piano hinge suitable for cladding

  • TS83 door closer

  • Panic exit device

  • Two-way extension rods

  • Night latch and handles

  • Sequence selector

Certification

 

  • Fire tested to AS 1530.4:2015

  • Complies with AS 1905.1:2015

Hardware

DURASUB

D - EXT - 1 

​

AUSTRALIAN 

STANDARDS

AS 1905:2015

Contact Durasteel Fire & Blast Doors Australia